8400 StateLine C | Reference manual
Motor control (MCTRL)
Internal interfaces | system block "LS_MotorInterface"
250 L Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
bIdentificationActive
BOOL
"Motor parameter identification active" status signal
Automatic motor data identification
( 112)
TRUE Motor parameter identification is active
bFlyingSyncActive
BOOL
"Flying restart function active" status signal
Flying restart function
( 200)
TRUE Flying restart function is active
bHlgLoad
BOOL
Control signal for an additional loading function of the ramp function generator
• L_NSet_1
.bExternalCINH
• To enable the ramp function generator to follow automatically when the
controller is inhibited, for jerk-free setpoint connection.
TRUE Set the ramp function generator to a setpoint of nHlgSetValue_a
nHlgSetValue_a
INT
Setpoint for an additional loading function of the ramp function generator
• L_NSet_1
.nCInhVal_a
• For speed-controlled drive tasks, the current actual speed value (e.g. in case of an
active pulse inhibit, flying restart function, controller inhibit) is provided at this
output.
• Scaling: 16384 ≡ 100 % reference speed (C00011
)
bHlgStop
BOOL
Control signal for stopping the ramp function generator (L_NSet_1)
TRUE Stop the ramp function generator
Identifier
DIS code | data type
Value/meaning