Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011 L 269
8400 StateLine C | Reference manual
I/O terminals
Digital terminals
Parameter
Function at constant input value
Selection: C02844/1
= "0: Loading with level" or "1: Loading with edge"
[6-2] Switching performance if the overflow is in the positive direction
If "0: Loading with level" is selected in C02844/1, the bPosIn12_Load input is status-
controlled: In case of a TRUE signal, the integrator is loaded with the value at
dnPosIn12_Set_p and the bPosIn12_State output is set to FALSE.
If "1: Loading with edge" is selected in C02844/1
, the bPosIn12_Load input is edge-
controlled: In case of a FALSE/TRUE edge, the integrator is loaded with the value at
dnPosIn12_Set_p and then immediately continues to integrate, the bPosIn12_State
output is set to FALSE.
A positive nFreqIn12_v signal is incremented (the counter content is increased with
every cycle).
A negative nFreqIn12_v signal is decremented (the counter content is reduced with
every cycle).
Parameter Possible settings Info
C02844/1
Function
0 Loading with level Load integrator with TRUE level at
the bPosIn12_Load input (Lenze
setting).
1 Loading with edge Load integrator with FALSE/TRUE
edge at the bPosIn12_Load input.
2 Loading with level + reset Load integrator when reaching the
comparison value or with TRUE level
at the bPosIn12_Load input.
C02845
0 2000000000 Comparison value
• Is valid for both the positive and
the negative value range.
• Lenze setting: 0
n Overflow at ±2147483648 incr. (±32767 encoder revolutions)
o C02845
: Comparison value (applies to both positive and negative value range)