EasyManua.ls Logo

Lenze 8400 StateLine C - Page 353

Lenze 8400 StateLine C
891 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 11.00 - DMS 8.0 EN - 10/2011 L 353
8400 StateLine C | Reference manual
Basic drive functions (MCK)
Internal interfaces | System block "LS_MotionControlKernel"
In the interconnection previously shown, the Motion Control Kernel monitors every
interface. Some of the signals such as a quick stop request or a DC-injection braking
request are directly passed through to the motor control. However, other signals are
passed through or modified depending on the operating mode (e.g. synchronising a
setpoint selection via ramp function).
8.2 Internal interfaces | System block "LS_MotionControlKernel"
In the Function Block editor, the system block LS_MotionControlKernel provides the
interfaces to the Motion Control Kernel.
Inputs
Identifier
Data type
Information/possible settings
Control and setpoint signals for motor control
The purpose of the following inputs is to transfer control signals and setpoints to the internal motor control
function (LS_MotorInterface
).
bPosCtrlOn Inputs have no function on the 8400 StateLine!
bDeltaPosOn
dnDeltaPos_p
dnPosSetValue_p
bPosDerivativeOn
bMotorRefOffsetOn
dnMotorRefOffset_p
bQspOn
BOOL
Trigger quick stop (QSP) via the MCK
Also see device command "Activate/Deactivate quick stop
".
TRUE Activate quick stop
Motor control is decoupled from the setpoint selection and,
within the deceleration time parameterised in C00105
, the motor
is brought to a standstill (n
act
=0).
A pulse inhibit (CINH) is set if the auto DCB function has been
activated via C00019
.
The motor is kept at a standstill during closed-loop operation
(function in preparation).
FALSE Deactivate quick stop
The quick stop is deactivated if no other source for the quick stop
is active.
C00159
displays a bit code of active sources/causes for the quick
stop.
nPWMAngleOffset
INT
Angular offset input
Scaling: 16384 100 %
Setting range: 0 ... 199.99 %
bSpeedCtrlIOn
BOOL
Directly set the I-component of speed controller
In order to statically specify a minimum torque, e.g. when a load is being lifted.
TRUE Se the I-component of the speed controller to the value
nSpeedCtrlI_a.
nSpeedCtrlI_a
INT
I-component of the speed controller
Value is adopted in the case of a FALSE-TRUE edge at the input bSpeedCtrlIOn.
nSpeedSetValue_a
INT
Rotation speed/velocity setpoint
bTorquemodeOn
BOOL
TRUE Switch on torque-controlled operation
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com