Firmware 11.00 - DMS 8.0 EN - 10/2011 L 379
8400 StateLine C | Reference manual
Basic drive functions (MCK)
Holding brake control
Selection of the feedforward control value
From version 11.00.00, the feedforward control value can be selected via bit 4 in C02582
:
Bit 4 = 0: Automatic selection
The torque saved at the last stop is used.
Bit 4 = 1: Manual selection
bMBrakeStartValue2 = FALSE: The feedforward control value 1 set in C02581/4
is
used.
bMBrakeStartValue2 = TRUE: The feedforward control value set in C02581/5
is used.
Related topics:
Functional settings
( 368)
Switching thresholds
( 369)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com