Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011 L 45
8400 StateLine C | Reference manual
Introduction: Parameterising the controller
Device access protection
Short overview of the relevant parameters for device personalisation:
Activating device personalisation
The device personalisation is activated by setting a binding ID.
How to set a binding ID:
1. Enter the desired binding ID in C00505/2
.
• The binding ID can have a maximum length of 16 characters.
• The binding ID may contain the following characters:
lower case letters (a - z), upper case letters (A - Z), digits (0 - 9)
2. Execute "Set binding ID" device command C00002/29
= "1: On / start"
• After successful execution, status ON is displayed in C00505/2
.
Parameter Info Lenze setting
C00505/2
Binding ID
• The binding ID can have a maximum length of 16 characters.
• The binding ID may contain the following characters:
lower case letters (a - z), upper case letters (A - Z), digits (0 - 9)
Note:
After the execution
of one of the device commands listed below, this
parameter provides the current binding ID status:
OFF No binding ID has been set.
ON Binding ID has been set.
Device commands
Before
the following device commands are executed, enter the corresponding binding ID in C00505/2.
C00002/29
Set binding ID
Activating device personalisation
0: Off / ready
C00002/30
Delete binding ID
Deactivating the device personalisation/changing the binding ID
0: Off / ready
Status displays
C00003 Status of the last device command -
C00507/1 Password protection - all communication channels
• Bit coded display of the active protective functions:
-
Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection
Bit 3 ... 14 Reserved
Bit 16 Memory module binding on
Highlighted in grey = display parameter