Address Name / seng range / [default seng] Informaon
0x2631:022
(P400.22)
Funcon list: Acvate setpoint via HTL input
(Funcon list: Setp: HTL input)
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate setpoint via HTL input"
funcon.
Trigger = TRUE: HTL input is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
Funcon is not supported in this device.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:025
(P400.25)
Funcon list: Acvate MOP setpoint
(Funcon list: Setp: MOP)
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate MOP setpoint" funcon.
Trigger = TRUE: the "Motor potenometer" funcon is used as setpoint
source (if the trigger assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:026
(P400.26)
Funcon list: Acvate segment setpoint (bit 0)
(Funcon list: Setp: Segment b0)
•
From version 03.00
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate segment setpoint (bit 0)"
funcon.
Selecon bit with the valency 20 for the bit-coded selecon and
acvaon of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
•
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
•
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:027
(P400.27)
Funcon list: Acvate segment setpoint (bit 1)
(Funcon list: Setp: Segment b1)
•
Fr
om version 03.00
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate segment setpoint (bit 1)"
funcon.
Selecon bit with the valency 2
1
for the bit-coded selecon and
acvaon of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
•
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
•
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:028
(P400.28)
Funcon list: Acvate segment setpoint (bit 2)
(Funcon list: Setp: Segment b2)
•
From version 03.00
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate segment setpoint (bit 2)"
funcon.
Selecon bit with the valency 2
2
for the bit coded selecon and
acvaon of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
•
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
•
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:029
(P400.29)
Funcon list: Acvate segment setpoint´(bit 3)
(Funcon list: Setp: Segment b3)
•
From version 03.00
•
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate segment setpoint´(bit 3)"
funcon.
Selecon bit with the valency 2
3
for the bit coded selecon and
acvaon of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
•
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
•
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
Conguring the frequency control
Changing the se
tpoint source during operaon
113