Parameter
Address Name / seng range / [default seng] Informaon
0x2824
(P200.00)
Control selecon
(Control select.)
Selecon of the type of inverter control.
0 Flexible I/O conguraon This selecon enables a exible assignment of the start, stop, and
rotang
direcon commands with digital signal sources.
Digital signal sources can be digital inputs, network and keypad.
The I/O conguraon is made via the parameters 0x2631:xx (P400.xx).
1 Keypad This selecon enables the motor to be started exclusively via the start
k
ey of the keypad. Other signal sources for starng the motor are
ignored.
Start motor Stop motor
Not
e!
The funcons "Enable inverter" 0x2631:001 (P400.01) and "Run"
0x2631:002 (P400.02) must be set to TRUE to start the motor.
If jog operaon is acve, the motor cannot be stopped via the
keypad key.
Start, stop and rotang
direcon commands
Control selecon
44