Parameter
Address Name / seng range / [default seng] Informaon
0x2631:001
(P400.01)
Funcon list: Enable inverter
(Funcon list: Enable inverter)
Seng can only be changed if the inverter is
disabled.
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the "Enable inverter" funcon.
Trigger = TRUE: The inverter is enabled (unless there is another cause for
in
verter disable).
Trigger = FALSE: The inverter is disabled.
Notes:
This funcon must be set to TRUE to start the motor. The signal TRUE
is acvated either via an assigned digital input or the default seng
"Constant TRUE [1]".
Changing to the inhibited state causes an immediate stop of the
motor, regardless of the stop method set in 0x2838:003 (P203.03).
The motor has no torque and coasts down.
The cause(s) for the inhibited state are shown in 0x282A:001
(P126.01).
4Example: Enable inverter ^ 56
1 Constant TRUE Trigger is constantly TRUE.
0x2631:002
(P400.02)
Funcon list: Run
(Funcon list: Run)
Seng can only be changed if the inverter is
disabled.
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger to the "Runfuncon.
Funcon 1: Start / stop motor (default seng)
Funcon 1 is acve if no further starng commands (start forward/start
r
everse) have been connected to triggers, no keypad control is acve and
no network control is acve.
Trigger = TRUE: Let motor rotate forward (CW).
Trigger = FALSE: Stop motor.
Notes to funcon 1:
If "Enable inverter" 0x2631:001 (P400.01) is set = "Constant TRUE [1]",
the only permissible trigger for this funcon is a digital input in order
that the motor can be stopped again any me.
The s
top method can be selected in 0x2838:003 (P203.03).
The funcon also serves to realize an automac start aer switch-on.
4St
art behavior ^ 33
4Example: Start/stop (1 signal) and reversal ^ 54
Funcon 2: Start enable/stop motor
Funcon 2 is acve if further starng commands have been connected
t
o triggers, keypad control is acve or network control is acve.
Trigger = TRUE: Startbefehle der akven Steuerquelle sind freigeben.
Trigger = FALSE: Stop motor.
Notes to funcon 2:
If no separate start enable is required for the applicaon, the trigger
"Constant TRUE [1]" must be set.
The stop method can be selected in 0x2838:003 (P203.03).
11 Digital input 1 State of X3/DI1, taking an inversion set in 0x2632:001 (P411.01) into
consideraon.
0x2631:003
(P400.03)
Funcon list: Acvate quick stop
(Funcon list: Quick stop)
Seng can only be changed if the inverter is
disabled.
Further possible sengs: 4T
rigger list ^ 52
Assignment of a trigger for the
"Acvate quick stop" funcon.
Trigger = TRUE: Acvate quick stop.
Trigger = FALSE: Deacvate quick stop.
Notes:
The "Quick stop" funcon brings the motor to a standsll within the
deceleraon me set in 0x291C (P225.00).
4Example: Quick stop^ 55
0 Not connected No trigger assigned (trigger is constantly FALSE).
Start, stop and rotang
direcon commands
Flexible I/O conguraon of the start, stop and rotang direcon commands
49