Address Name / seng range / [default seng] Informaon
0x4026:002
(P801.02)
Sequencer segment 1: Acceleraon/deceleraon
(Segment 1: Accel./decel.)
0.0 ... [5.0] ... 3600.0
s
From version 03.00
Acceleraon/deceleraon for the segment.
Only relevant for operang mode 0x6060 (P301.00) = "MS: Velocity
mode [-2]".
The set me refers to the acceleraon from standsll to the set
maximum frequency. The deceleraon is eected with the same
ramp.
0x4026:003
(P801.03)
Sequencer segment 1: Time
(Segment 1: Time)
0.0 ... [0.0] ... 100000.0 s
From version 03.00
Runme for the segment aer the expiry of which it is switched over to
the next step of the sequence.
Only relevant for Sequencer mode 0x4025 (P800.00) = "Time
operaon [1]" or "Time & step operaon [3]".
With the seng "0.0", the segment will be skipped.
0x4026:004
(P801.04)
Sequencer segment 1: Digital outputs
(Segmen
t 1: Digital outp.)
0 ... [0] ... 255
From version 03.00
Oponally: Set digital outputs to the level set here for the execuon
me of the segment.
Note! In order that the control of a digital output is executed by the
sequencer, the following assignment must be made for the respecve
digital output:
Relay: 0x2634:001 (P420.01) = "Sequencer controlled [100]"
Digital output 1: 0x2634:002 (P420.02) = "Sequencer controlled [100]"
Bit 0 Relay 0 = X9/NO-COM open and NC-COM closed.
1 = X9/NO-C
OM closed and NC-COM open.
An inversion set in 0x2635:001 (P421.01)is taken into consideraon
here.
Bit 1 Digital output 1 0 = set digital output 1 to LOW level.
1 = set digital output 1 to HIGH level.
An inversion set in 0x2635:002 (P421.02) is taken into consideraon
here.
Bit 2 Digital output 2 Funcon is not supported in this device.
0x4026:005
(P801.05)
Sequencer segment 1: Analog outputs
(Segmen
t 1: Analog outp.)
0.00 ... [0.00] ... 10.00 VDC
From version 03.00
Oponally: Set analog output to the voltage value set here for the
execuon me of the segment.
Note! In order that the control of the analog output is executed by the
sequencer, the following assignment must be made for the analog
output:
Analog output 1: 0x2639:002 (P440.02) = "Sequencer controlled [10]"
0x4026:006
(P801.06)
Sequencer segment 1: PID setpoint
(Segment 1: PID setp.)
-300.00 ... [0.00] ... 300.00 PID unit
From version 03.00
PID control value for the segment.
Only relevant if the PID control in 0x4020:001 (P600.01) is acvated.
0x4026:007
(P801.07)
Sequencer segment 1: Torque setpoint
(Segment 1: Torque setp.)
-400.0 ... [100.0] ... 400.0 %
From version 03.00
Torque setpoint for the segment.
Only relevant for operang mode 0x6060 (P301.00) = "MS: Torque
mode [-1]".
0x4026:008 Sequencer segment 1: NetWordOUT2
0 ... [0] ... 65535
From version 03.00
Funcon is not supported in this device.
0x4026:009 Sequencer segment 1: Reserved
0 ... [0] ... 4294967295.0
From version 03.00
0x4027:001
(P802.01)
Sequencer segment 2: Frequency setpoint
(Segment 2: Frequency setp.)
-599.0 ... [0.0] ... 599.0 Hz
From version 03.00
Frequency setpoint for the segment.
Only relevant for operang mode 0x6060 (P301.00) = "MS: Velocity
mode [-2]".
Direcon of rotaon according to sign.
0x4027:002
(P802.02)
Sequencer segment 2: Acceleraon/deceleraon
(Segment 2: Accel./decel.)
0.0 ... [5.0] ... 3600.0 s
From version 03.00
Acceleraon/deceleraon for the segment.
Only relevant for operang mode 0x6060 (P301.00) = "MS: Velocity
mode [-2]".
The set me refers to the acceleraon from standsll to the set
maximum frequency. The deceleraon is eected with the same
ramp.
0x4027:003
(P802.03)
Sequencer segment 2: Time
(Segmen
t 2: Time)
0.0 ... [0.0] ... 100000.0 s
From version 03.00
Runme for the segment aer the expiry of which it is switched over to
the next step of the sequence.
Only relevant for Sequencer mode 0x4025 (P800.00) = "Time
operaon [1]" or "Time & step operaon [3]".
With the seng "0.0", the segment will be skipped.