102
Error Messages, continued
Error
Identification
and Description,
continued
Continued on next page
Error
Code
Error (Fault) Possible Cause/Corrective Action
F06 Motor overtemperature. - I
rms
or I
peak
set too high.
- Defective motor
- If motor is not hot, check feedback cables and
connectors.
- Reduce motion profile duty cycle
- Improve ventilation of the motor
F07 Internal 24 Vdc fault. Return drive to manufacturer
F08* Motor speed limit
exceeded.
- Feedback parameters not set correctly.
- Incorrect feedback wiring.
- Motor phases reversed.
- Check Parameter “Overspeed” for correct setting.
F09 EEPROM checksum error. Return drive to manufacturer.
F10 Flash-EPROM checksum
error.
Return drive to manufacturer.
F11 Motor brake fault. - Brake parameter set to “WITH” when brake does not
exist.
- Defective brake.
- Check motor power cable and connections.
F12 Motor phase missing. - Defective motor.
- Check motor power cable and connections
F13* Drive internal temperature
exceeded.
- Improve ventilation.
- Reduce motion profile duty cycle.