Gocator Snapshot Sensors: User Manual
Gocator Device Files • 339
Element Type Description
StreamOptions Collection
A collection of StreamOptions on page 326 elements.
Stream\Step
32s The stream source step. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
Stream\Id 32u The stream source ID.
RefLine
ProfileLine
Definition of reference line. Ignored if RefType is not 0.
Line
ProfileLine
Definition of line.
Measurements\X Intersect tool
measurement
X measurement.
Measurements\Z Intersect tool
measurement
Z measurement.
Measurements\Angle Intersect tool
measurement
Angle measurement.
Features\IntersectPoint
GeometricFeature
IntersectPoint PointFeature.
Features\Line GeometricFeature Line LineFeature.
Features\BaseLine GeometricFeature BaseLine LineFeature.
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
PreserveInvalidsEnabled Boolean Preserve invalid measurements enable state
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Intersect Tool Measurement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 3210 and is the answer not in the manual?

LMI Technologies Gocator 3210 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 3210
CategoryAccessories
LanguageEnglish

Related product manuals