Gocator Snapshot Sensors: User Manual
Protocols • 394
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x3013)
dhcpEnabled byte 6 0 – DHCP not used
1 – DHCP used
address[4] byte 7 IP address (most significant byte first).
subnetMask[4] byte 11 Subnet mask.
gateway[4] byte 15 Gateway address.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x3013).
status 32s
6
Reply status. For a list of status codes, see Commands on page
388.
Reply
Get System Info V2
The Get System Info command reports information about the local node, remote nodes and assigned
buddies.
Firmware version refers to the version of the Gocator's firmware installed on each individual sensor. The
client can upgrade the Gocator's firmware by sending the Start Upgrade command (see Start Upgrade on
page 427). Firmware upgrade files are available from the downloads section under the support tab on
the LMI web site. For more information on getting the latest firmware, see Firmware Upgrade on page
70.
Every Gocator sensor contains factory backup firmware. If a firmware upgrade command fails (e.g.,
power is interrupted), the factory backup firmware will be loaded when the sensor is reset or power
cycled. In this case, the sensors will fall back to the factory default IP address. To avoid IP address
conflicts in a multi-sensor system, connect to one sensor at a time and re-attempt the firmware upgrade.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4010)
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4010).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
Reply