Gocator Snapshot Sensors: User Manual
Protocols • 431
Field Type Offset Description
Bits 0-14: Message type identifier. For this message, set to 8.
attributeSize 16u 6 Size of attributes, in bytes (min: 40, current: 48).
length (L) 32u 8 Surface length (rows).
length (W) 32u 12 Surface width (columns).
xScale 32u 16 X scale (nm).
yScale 32u 20 Y scale (nm).
zScale 32u 24 Z scale (nm).
xOffset 32s 28 X offset (µm).
yOffset 32s 32 Y offset (µm).
zOffset 32s 36 Z offset (µm).
source 8u 40 Source
0 – Top
1 – Bottom
2 – Top Left
3 – Top Right
exposure 32u 41 Exposure (ns).
reserved[7] 8u 45 Reserved.
streamStep 32s 52
Data stream step number. For a surface, values are:
3 – surface stream step
8 – tool data stream step
streamStepId 32s 56 Data stream step identifier within the stream step.
ranges[L][W] 16s 60 Surface ranges.
Surface Intensity
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 9.
attributeSize 16u 6 Size of attributes, in bytes (min: 32, current: 32).
length (L) 32u 8 Surface length (rows).
width (W) 32u 12 Surface width (columns).
xScale 32u 16 X scale (nm).
yScale 32u 20 Y scale (nm).
xOffset 32s 24 X offset (µm).
yOffset 32s 28 Y offset (µm).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 3210 and is the answer not in the manual?

LMI Technologies Gocator 3210 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 3210
CategoryAccessories
LanguageEnglish

Related product manuals