Gocator Snapshot Sensors: User Manual
Protocols • 405
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4104).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
reference 32s 10 Alignment reference
0 – Fixed
1 – Dynamic
Reply
Set Alignment Reference
The Set Alignment Reference command is used to set the sensor's alignment reference.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4103).
reference 32s 6 Alignment reference
0 – Fixed
1 – Dynamic
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4103).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
Reply
Clear Alignment
The Clear Alignment command clears sensor alignment.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4102).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4102).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
Reply

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 3210 and is the answer not in the manual?

LMI Technologies Gocator 3210 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 3210
CategoryAccessories
LanguageEnglish

Related product manuals