EasyManuals Logo

LMI Technologies Gocator 3210 User Manual

Default Icon
563 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #402 background imageLoading...
Page #402 background image
Gocator Snapshot Sensors: User Manual
Protocols • 402
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x1006).
name[64] char 6 Source file name.
length 32u
70
File length.
data[length] byte 74 File contents.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x1006).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
Reply
Delete File
The Delete File command removes a file from the connected sensor (a .job file, a component of a job file,
or another type of file; for more information, see Job File Structure on page 300).
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x1008).
name[64] char 6 Source file name.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x1008).
status 32s 6
Reply status. For a list of status codes, see Commands on page
388.
Reply
User Storage Used
The User Storage Usedcommand returns the amount of user storage that is used.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x1021).
Command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 3210 and is the answer not in the manual?

LMI Technologies Gocator 3210 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 3210
CategoryAccessories
LanguageEnglish

Related product manuals