363-206-305 Circuit Order:
NTP-006
Issue 3, June 2000 Page 5 of 6
DDM-2000 F
IBER
R
EACH
W
IDEBAND
S
HELF
DO ITEMS BELOW IN ORDER LISTED . . . . FOR DETAILS, GO TO
8. Make necessary VT1.5/STS1 cross-connections for each node in
the network.
DLP-526A. Single/Dual Homed OC-3/OC-1 Configuration
DLP-535B. Single/Dual Homed OC-12/OC-3 Configuration
DLP-530C. Single/Dual Homed OC-48/OC-3 or OC-12 Configuration
DLP-528D. Stand Alone OC-3/OC-1 Ring Configuration
9. For a DS1 circuit in a path protected ring network, the
sw-path-( ):
address
command must be used at the
terminating nodes to switch the active VT1.5 (DS1) path to repeat
this test on the other path(s).
DLP-510Perform DS1 end-to-end transmission test for each circuit being
put into service.
10. Use the rtrv-state: command to determine the port state of
the DS1 port(s) of the circuit being established.
11.
NOTE:
If a port is in the
nmon (n)
state, the signal is not monitored
or alarmed. The port will not automatically go to the
in
service (i)
state when a signal is detected as it will in the
auto
(a)
state. In the
nmon
state, the port must be returned to the
auto
state, using the set-state-t1: command, to turn on
monitoring of signal failures and before any circuit packs
associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t1: command to set the port state of the
DS1 port(s) of the circuit being established.
12. If BBF3 DS1PM circuit packs are installed and the optional
ds1pm
performance monitoring feature is to be used, use the
set-feat:feat=ds1pm,act=enable command to enable the
feature.