C06-03
SwiftLift REVSpd (V/f and OLV)
UltraLift REVSpd (FLV)
60.0 0.1–150.0 Hz Page 96
C06-04
SL FWD Current (V/f)
SL FWD Torque (OLV)
UL FWD Torque (FLV)
50 0–100 % Page 96
C06-05
SL REV Current (V/f)
SL REV Torque (OLV)
UL REV Torque (FLV)
30 0–100 % Page 96
C06-06
SL Enabling Spd (V/f and OLV)
UL Enabling Spd (FLV)
59.0 0.0–150.0 Hz Page 96
C06-07
SL Delay Time (V/f and OLV)
UL Delay Time (FLV)
2.0 0.0–25.5 sec Page 96
C06-08 SFS Acc Gain 1.0 0.1–9.9 - Page 96
C06-10 Mtr Trq Quickset 3 0–5 - Page 96
C06-11 Motor Torque 1 45 1–100 % Page 96
C06-12 Motor Speed 1 90.0 0.0–150.0 Hz Page 96
C06-13 Motor Torque 2 25 1–100 % Page 96
C06-14 Motor Speed 2 120.0 1.0–150.0 Hz Page 96
C06-15 AUL FWD Offset 10 0–100 % Page 96
C06-16 AUL REV Offset 20 0–100 % Page 96
C07-01 Trq Limit FWD 150 0–300 % Page 99
C07-02 Trq Limit REV 150 0–300 % Page 99
C07-03 Trq Lmt FWD Rgn 180 0–300 % Page 99
C07-04 Trq Lmt REV Rgn 180 0–300 % Page 99
C07-05 T-Lim FWD Gain 1.25 0.00–2.55 - Page 99
C07-06 T-Lim REV Gain 1.25 0.00–2.55 - Page 99
C07-07 T-Lim RGN Gain 1.25 0.00–2.55 - Page 99
C07-08 Trq Lim I Time 200 5–10000 ms Page 99
C07-09 Torque Limit Sel 0 0, 1 - Page 99
C07-10 Trav Trq Limiter 0 0, 1 - Page 99
C07-11 Limiter Freq 2.0 0.5–10.0 Hz Page 99
C07-12 Anti-Shock 0 0–2 - Page 101
C07-13 Enabling Freq 6.0 0.0–60.0 Hz Page 101
C07-14 Re-Accel Delay 0.20 0.00–2.55 sec Page 101
C07-15 Torque Delta 10 0–180 % Page 101
C07-16 Detection Time 0.30 0.01–0.50 sec Page 101
C07-17 Smoothing Freq 3.0 0.0–15.0 Hz Page 101
C07-18 Smoothing Time 1.00 0.00–2.55 sec Page 101
C07-20 Steadying Time 0.20 0.00–0.50 sec Page 101
C07-22 AlarmDisplayTime 4 0–30 sec Page 101
C07-23 No Load Torque 20 0–100 % Page 101
C07-24 Required Torque 75 0–180 % Page 101
C07-25 Detection Method 1 0–2 - Page 101
C08-01 Torque Comp Time 1.00 0.00–2.55 - Page 104