76 12. View data – Programming Manual
12.3.1.
Gap control data
Reference of Gap control limit
Gap control limit value = absolute value
Gap control limit value = relative value
Gap control trigger modality
The Gap output control is triggered when the noise level exceeds limit S1.
The Gap output control is triggered when the noise level drops below limit
S1.
Gap control self-locking
Self-locked control. Once supplied, the Gap output control is reset only
after the successive start cycle.
NON self-locked control. The Gap output control is reset when the noise
level drops below the S1 trigger limit.
12.3.2.
Crash control data
Gap control
trigger modality
Gap control limit (S1)
Delay on Gap control limit
Reference of Gap control limit
Gap control self-locking
Crash control
trigger modality
Crash control limit (S2)
Delay on Crash control limit
Crash control self-locking
Value of the filter on the Gap
background noise