EasyManua.ls Logo

marposs P7WB - Viewing Supervision Data

Default Icon
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– Programming Manual 12. View data 77
Crash control trigger modality
The Crash output control is triggered when the noise level exceeds limit
S1.
The Crash output control is triggered when the noise level drops below
limit S1.
Crash control self-locking
Self-locked control. Once supplied the Crash output control is reset only at
the successive Crash control enabling.
NON self-locked control. The Crash output control is reset when the noise
level drops below the S1 trigger limit.
12.4.
Viewing supervision data
Page D4 of the “Utilities” folder menu map (section 8.1, page 3).
RPM Min – Minimum wheel rotation
speed
RPM Max – Maximum wheel rotation
speed
RPM – Speed programmed for the
wheel rotation in case the
rotation speed sensor is not
used.