Page 203
Appendix| Control Menu
optoNCDT 2300
Load/save
settings
Data selection for
transmission
Setup / Material data base A parameter set contains settings for measuring, for exam-
ple measuring rate and the interface settings. The material
data base contains refractive indices of different materials.
Setup no.: 1 / 2 / 3 ... 8 Selection of the set of parameters to be load/save. The user
selects a number when loading/saving a complete configu-
ration. Allows fast duplicating of parameter sets.
Export setup Button If you press Export, the download manager of your brows-
er opens and offers to save the setting values in a specified
file “setup. meo“ in the PC.
Keep interface
settings
Checkbox You should load the interface settings only when the sensor
is operated on different networks respectively with different
baud rates of the RS422 interface.
Browse / Import Button If you press Browse ... Windows opens the selection
window to select a configuration file saved in the PC. By
opening the selected file in the selection window, the path
is cached. Loading the file will be effected by the Import
button.
Extras Language German / English Language of the interactive websites.
Unit mm / inch Units in the measurement representation
Factory setting Reset material
data base only
Checkbox Allows to replace only the values in the material database.
Keep interface
settings
Checkbox This enables to leave all the settings for the
Ethernet and the RS422 interface unchanged.
Selection required or checkbox
i
The settings will be effective, if you click on the button Apply. After the program-
ming, all settings must be permanently stored under a parameter set, so that they
are available again when the sensor is switched on the next time.
Value Specification of a value required