Page 24
Functional Principle, Technical Data
optoNCDT 2300
Model ILD2300-2DR/R ILD2300-2DR/BL
Measuring range
1
mm (inches) 2 / 1 (.08 / .04)
Start of measuring range
1
mm (inches) 9 / 9 (.35 / .35)
Midrange
1
mm (inches) 10 / 9.5 (.39 / .37)
End of measuring range
1
mm (inches) 11 / 10 (.43 / .39)
Measuring rate
7 adjustable stages: 49.14 kHz
2
/ 30 kHz / 20 kHz / 10 kHz / 5 kHz / 2. kHz / 1.5 kHz
Linearity < ± 0.6 µm (< ± 0.03 % FSO)
Resolution
3
µm 0.03
Temperature stability
4
± 0.01 % FSO / K
Spot diameter (± 10 %)
5
SMR, µm 21.6 x 25
MMR, µm 8.5 x 11
EMR, µm 22.4 x 23.7
Light source Semiconductor laser < 1 mW, 670 nm (rot) Semiconductor laser < 1 mW, 405 nm (blue violoet)
Laser class Class 2 acc. to IEC 60825-1: 2014
Permissible ambient light 10,000 ... 40,000 lx
Power supply 11 … 30 VDC; < 3 W (24 V) 11 … 30 VDC; < 2 W (24 V)
Signal input Laser on/off, Sync in, Trigger in
Digital interface
RS422 (16 bit) / Ethernet / EtherCAT / PROFINET
6
/ EtherNet/IP
6
Analog output
6
4 … 20 mA / 0 … 5 V / 0 … 10 V / ± 5 V / ± 10 V
Temperature range Operation: 0 ... +50 °C (+32 °F up to +122 °F); storage: -20 ... +70 °C; (non-condensing)
Shock (DIN EN 60068-2-29) 15 g / 6 ms in 3 axis
Vibration (DIN EN 60068-2-6) 2 g / 20 … 500 Hz
Housing material, weight Aluminum; appr. 400 g (incl. pigtail)
FSO = Full Scale Output, SMR = Start of measuring range, MMR = Mid of measuring range, EMR = End of measuring range; The specified data ap-
ply to white, diffuse reflecting surfaces (Micro-Epsilon reference ceramic for ILD sensors)
1) Second value is valid for a measuring rate of 49.14 kHz 4) Based on digital output in midrange
2) Measuring rate of 49.14 kHz with reduced measuring range 5) Spot diameter determined for punctual laser with Gauß fitting (full 1/e² width)
3) Measuring rate of 20 kHz 6) Connection via interface module (see accessories)