6. General Procedures - The Diagnostic Tools Pages
206 Morgana DocuMaster MFC - Service Manual
1 GUi CPU replied with a NAK
2 Time-out, GUI CPU failed to reply fully.
3 UART fifo overflow in MFC
4 GUI CPU reply too long (Message buffer overflow)
5 GUI CPU failed to respond to ! K8 command
6 UART framing error in MFC
10 Data string returned by GUI CPU was malformed
11 Check sum on data string bad
20 Invalid code for MODE (M field)
21 Invalid length (L field)
22 Invalid fold distance (F field)
23 Invalid Offset (O field)
24 Invalid Skew (S field)
25 Invalid Hinge on/off (H field)
26 Invalid Hinge distance (D field)
27 Invalid SIZE
28 Invalid INSERT
29 INFO
30 WIDTH
31 NSHEETS
‘Y’ Manually Set the Solenoid Outputs
Not used.
Yn n = 0 Both outputs OFF.
n = 1 Solenoid 1 ON; Solenoid 2 OFF.
n = 2 Solenoid 1 OFF; Solenoid 2 ON.
n = 3 Both solenoids OFF.