Getting Started M6100 Broadcast Satellite Modulator
8 Getting Started
Use this guide to configure the management IP Address of the device and save it as a boot
configuration. Once this is done, it is possible to access the device using one of the following
operational interfaces:
• GUI;
• CLI;
• SNMP.
Refer to the reference manual to check the factory default values of the device.
8.1 Set the Management IP Address
The factory default of the Mgmt IP Address is: 10.0.0.2/24 on Mgmt1 Ethernet
interface.
» Insert the power cable to start the device;
» Wait until the welcome menu disappeared and the menu tree is displayed on the front panel;
» Select Mgmt Itf using the corresponding Soft Button;
» Navigate to IP Address;
» Press OK (to unfold the branch);
» Navigate to Mgmt1;
» Press OK;
» Press OK to select the IP Address/Prefix;
» Use the Soft Buttons to enter a new IP Address/Prefix;
» Press OK to confirm and save the setting;
» Connect an Ethernet cable between the Mgmt1 port on the back panel of the M6100 and the
management PC. (The state indication on the front panel is changed from off to on).
Note that only device specific parameter settings are automatically saved.
All other parameters require an explicit save action!
To get an overview of the device specific parameters we refer to section
ConfigurationFileonpage82