Features Descriptions M6100 Broadcast Satellite Modulator
12.9.5 Automated Linear Equalink™ using Internal test Traffic
Perform the Internal Test Traffic calibration procedure during uncritical hours!
This because the procedure is a quasi-non-service disruptive procedure.
The procedure causes about 15 small glitches (BBF error sequences).
Use the following procedure to perform automated Linear Equalink™ measurements.
» Login as expert user;
» Navigate to the device Tasks Pane (GUI);
» Click Equalink;
» Click Automated Linear