How to Manage the Device M6100 Broadcast Satellite Modulator
M6100 >> Device Setup >> Mgmt Interface >> IP Address >> Link Redundancy
When link redundancy is activated, the bond interface must be configured. This bond
interface has an IP Address that is used as destination address by the source.
To have bonding working properly make sure to configure the switch/router in such a
way that the spanning tree is not blocking the fast switchover between ports.
In a typical Cisco switch configured using rapid spanning tree this is achieved by
setting the ports in PortFast mode.