3-37
3-9 Parameter List
3
Operation
Others
b060
Window comparator
O upper limit level
Set an upper limit level.
Setting range: 0 to 100
Lower limit: Lower limit level + Hysteresis
width × 2
100 Yes %
4-66
b061
Window comparator
O lower limit level
Set a lower limit level.
Setting range: 0 to 100
Upper limit: Upper limit level - Hysteresis
width × 2
0Yes%
b062
Window comparator
O hysteresis width
Set a hysteresis width for the upper and lower
limit levels.
Setting range: 0 to 10
Upper limit: (Upper limit level - Lower limit
level) × 2
0Yes%
b063
Window comparator
OI upper limit level
Set an upper limit level.
Setting range: 0 to 100
Lower limit: Lower limit level + Hysteresis
width × 2
100 Yes %
b064
Window comparator
OI lower limit level
Set a lower limit level.
Setting range: 0 to 100
Upper limit: Upper limit level - Hysteresis
width × 2
0Yes%
b065
Window comparator
OI hysteresis width
Set a hysteresis width for the upper and lower
limit levels.
Setting range: 0 to 10
Upper limit: (Upper limit level - Lower limit
level) × 2
0Yes%
b066
Window comparator
O2 upper limit level
Set an upper limit level.
Setting range: -100 to 100
Lower limit: Lower limit level + Hysteresis
width × 2
100 Yes %
b067
Window comparator
O2 lower limit level
Set a lower limit level.
Setting range: -100 to 100
Upper limit: Upper limit level - Hysteresis
width × 2
-100 Yes %
4-66
b068
Window comparator
O2 hysteresis width
Set a hysteresis width for the upper and lower
limit levels.
Setting range: 0 to 10
Upper limit: (Upper limit level - Lower limit
level) × 2
0Yes%
b070
Analog operation
level at O
disconnection
0 to 100/no (ignored) no No
b071
Analog operation
level at OI
disconnection
0 to 100/no (ignored) no No
b072
Analog operation
level at O2
disconnection
-100 to 100/no (ignored) no No
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.