Section 7 System Settings 7-1 Settings
NS-Designer Operation Manual
No. Setting Details
1 Number of Opera-
tion Log Records
Set the number of logging records to be saved in a single file. The number of re-
cords can be set to between 0 and 1,024.
Set to 0 if it is not necessary to save records.
2 Use Ring Buffer Select to record data in a ring buffer. When this setting is selected, if the maximum
number of items is exceeded, the oldest data is deleted and the new data is re-
corded. When this setting is not selected, no more data will be recorded once the
set maximum is reached.
3 Character Code for
Log File
Select the character code (ASCII or Unicode) for alarm/event histories, data logs,
operation logs, and error logs.
4 Logfile Output
Format
Set the format for outputting the data log to a CSV file.
5 Save the data with
offset time display
format
Select to display the time as an offset when outputting log data from the data log
to a CSV file.
7-1-5 Comm-All