117
Specifying Addresses Section 7-3
*1 Enter addresses like this on the NV-Designer:
*2 Enter addresses like this on the NV-Designer:
*3 Enter addresses like this on the NV-Designer:
*4 The address that can be used depends on the model.
7-3-3 PT Internal Addresses
The following internal addresses in the PT can be accessed by functional
parts.
Note “WGR” is used to specify GR data in word units. For example, “WGR1” speci-
fies the 16 bits from GR10 to GR1F.
Word
addresses
I/O bits
Work bits
--- 0000 to 9999
LR Area L L 0000 to L 9999
SR Area A A 0000 to A 9999
HR Area H H 0000 to H 9999
Timer present values T T 0000 to T 4095
Counter present values C C 0000 to C 4095
Data Memory D D 00000 to D 32767
Work Area W W 0000 to W 9999
EM Area current bank EM EM 00000 to EM 32767
EM Area specified bank E E 0_00000 to E 18_32767 *3
Double-word
addresses
Index registers IR IR 00 to IR 15
Area Area specification in
pull-down list
Word Remarks
Word
Period
Bit position
.
Word
Period
Bit position
Underscore
Bank number
.
Word
Underscore
Bank number
Area Word
Bit addresses CIO Area GR 0 to GR 255F
Word addresses CIO Area WGR 0 to WGR 255
Data Memory GDT 0 to GDT 2047