5-27 Details on Important Parameters
Operating Functions
5
Adaptive Filter Table
The table number corresponding to the frequency for the adaptive filter is displayed.
This parameter is set automatically and cannot be changed when the adaptive filter is enabled
(when the Adaptive Filter Selection (Pn023) is 1 or 2).
When the adaptive filter is enabled, data will be saved in EEPROM every 30 min. If the adaptive
filter is enabled the next time the power supply is turned ON, adaptive operation will start with the
data saved in EEPROM as the default value.
To clear this parameter and reset the adaptive operation, disable the adaptive filter by setting the
Adaptive Filter Selection (Pn023) to 0, and then enable it again.
Pn02F Notch Filter 1 Frequency Pn02F Notch Filter 1 Frequency Pn02F Notch Filter 1 Frequency
0 (Disabled) 22 766 44 326
1 (Disabled) 23 737 45 314
2 (Disabled) 24 709 46 302
3 (Disabled) 25 68247 290
4 (Disabled) 26 656 48 279
51482 27 631 49 269 (Disabled when Pn022
F)
61426 28 607 50 258 (Disabled when Pn022
F)
71372 2958451248 (Disabled when Pn022
F)
8 1319 30 562 52 239 (Disabled when Pn022
F)
9 1269 31 540 53 230 (Disabled when Pn022
F)
10 1221 32 520 54 221 (Disabled when Pn022
E)
11 1174 33 500 55 213 (Disabled when Pn022
E)
12 1130 34 481 56 205 (Disabled when Pn022
E)
13 1087 35 462 57 197 (Disabled when Pn022
E)
14 1045 36 445 58 189 (Disabled when Pn022
E)
15 1005 37 428 59 182 (Disabled when Pn022
D)
16 967 38 412 60 (Disabled)
17 930 39 396 61 (Disabled)
18895 40 381 62 (Disabled)
19 861 41 366 63 (Disabled)
20 828 42 352 64 (Disabled)
21 796 43 339