Determine Which Fan Module Is Faulty
142 SPARC T5-8 Server Service Manual • November 2015
Determine Which Fan Module Is Faulty
The following LEDs are lit when a fan module fault is detected:
System Service Required LEDs on the front panel and rear I/O module
Server Fan Fail LED on the rear I/O module
Service Required LED on the faulty fan module
1.
Determine if the System Service Required LEDs are lit on the front panel.
See “Interpreting LEDs” on page 29.
2.
Determine if the Server Fan Fail LED on the front panel is lit.
See “Front Panel Controls and LEDs” on page 31.
3.
From the rear of the server, check the fan module LEDs to identify which fan
module needs to be replaced.
See “Fan Module LED” on page 141.
4.
Remove the faulty fan module.
See “Remove a Fan Module” on page 143.
Related Information
“Remove a Fan Module” on page 143
“Install a Fan Module” on page 145
“Verify the Fan Module” on page 146