Power Off the Server (Power Button - Graceful)
Preparing for Service 55
2.
Switch from the system console to the Oracle ILOM prompt by typing the #.
(Hash Period) key sequence.
3.
At the Oracle ILOM prompt, type the stop /System command.
4.
If you are servicing a cold-service component, or if you are upgrading the server,
disconnect the power cords.
See “Disconnect the Power Cords” on page 56.
Related Information
“Power Off the Server (Power Button - Graceful)” on page 55
“Disconnect the Power Cords” on page 56
“Configuring Boot and Restart Behavior” in SPARC and Netra SPARC T5 Series Servers
Administration Guide
Power Off the Server (Power Button - Graceful)
This procedure places the system in the power standby mode. To service cold-replaceable
components, you must remove the power.
1.
Press and release the recessed Power button.
The Power OK LED blinks rapidly.
2.
If you are servicing a cold-service component, or if you are upgrading the server,
disconnect the power cords.
See “Disconnect the Power Cords” on page 56.
Related Information
“Power Off the Server (SP Command)” on page 54
“Disconnect the Power Cords” on page 56
“Configuring Boot and Restart Behavior” in SPARC and Netra SPARC T5 Series Servers
Administration Guide
Power Off the Server (Emergency Shutdown)
This procedure places the system in the power standby mode. To service cold-replaceable
components, you must remove the power.

Table of Contents

Other manuals for Oracle SPARC T5-8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T5-8 and is the answer not in the manual?

Oracle SPARC T5-8 Specifications

General IconGeneral
BrandOracle
ModelSPARC T5-8
CategoryServer
LanguageEnglish

Related product manuals