Install the Battery
Servicing the Battery 125
Install the Battery
1.
Insert the new battery in the main module, with the positive side (+) facing out.
2.
Install the main module back into the server.
See “Install the Main Module” on page 95.
If the SP is configured to synchronize with a network time server using the Network Time
Protocol, the Oracle ILOM clock will be reset as soon as the server is powered on and
connected to the network. Otherwise, proceed to the next step.
3.
If the SP is not configured to use NTP, use the Oracle ILOM clock command to
set the day and time.
The following example sets the date to June 17, 2013.
-> set /SP/clock datetime=061716192010
-> show /SP/clock
/SP/clock
Targets:
Properties:
datetime = Wed JUN 17 16:19:56 2013
timezone = GMT (GMT)
usentpserver = disabled
Commands:
cd