Verify the Service Processor Card
114 SPARC T5-8 Server Service Manual • November 2015
b.
Download the system firmware.
Follow the firmware download instructions in the Oracle ILOM documentation.
Note - You can load any supported system firmware version, including the firmware revision
that had been installed prior to the replacement of the service processor card.
8.
Restore the SP configuration information.
-> cd /SP/config
-> load -source uri target
where:
■
The acceptable values for uri are tftp, ftp, sftp, scp, http, and https.
■
target is the remote location where you stored the configuration information.
For example:
-> load -source tftp://129.99.99.99/pathname
9.
Verify the installation of the service processor card.
See “Verify the Service Processor Card” on page 114.
Related Information
■
“Remove the Service Processor Card” on page 110
■
“Verify the Service Processor Card” on page 114
Verify the Service Processor Card
1.
Ensure that you have completed the following:
■
Applied power to the server.
See “Connect the Power Cords” on page 191.
■
Started the system.
See “Power On the Server (Oracle ILOM)” on page 192.
2.
Verify that the SP LED on the main module or rear I/O module is lit green.
See “Front Panel Controls and LEDs” on page 31 or “Rear Panel Controls and
LEDs” on page 33.
If the SP LED is lit, see “Diagnostics Process” on page 25.