Run POST With Maximum Testing
40 SPARC T5-8 Server Service Manual • November 2015
Commands:
cd
set
show
->
Related Information
“POST Overview” on page 35
“Oracle ILOM Properties That Affect POST Behavior” on page 35
“Run POST With Maximum Testing” on page 40
Oracle ILOM Documentation Library
Run POST With Maximum Testing
This procedure describes how to configure the server to run the maximum level of POST.
1.
Log in to Oracle ILOM.
See “Log In to Oracle ILOM (Service)” on page 28.
2.
Set the virtual keyswitch to diag so that POST runs in service mode.
Alternatively, you can use the /System target.
-> set /HOST keyswitch_state=diag
Set 'keyswitch_state' to 'Diag'
3.
Run POST.
Alternatively, you can use the /System target.
-> start /SYS
Are you sure you want to start /SYS (y/n)? y
Starting /SYS
4.
Start the system console to view the output of the tests.
-> start /HOST/console