Verify the Processor Module
70 SPARC T5-8 Server Service Manual • November 2015
Related Information
■
“Servicing DIMMs”
■
“Verify the Processor Module” on page 70
■
“Server Upgrade Process” on page 59
Verify the Processor Module
1.
Ensure that you have completed the following:
■
Applied power to the server.
See “Connect the Power Cords” on page 191.
■
Started the system.
See “Power On the Server (Oracle ILOM)” on page 192.
2.
If you replaced a faulty PM, log in to the fmadm shell, and use the fmadm faulty
command to determine if a fault on the PM is shown:
-> start /SP/faultmgmt/shell
Do you want to start the /SP/faultmgmt/shell (y/n)? y
faultmgmtsp> fmadm faulty
a.
If the output shows the replacement PM as enabled, go to Step 3.
b.
If the output shows the replacement PM as disabled, go to “Detecting and
Managing Faults” to clear the fault from the server.
3.
Verify that the OK LED is lit on the PM and that the Fault LED is not lit.
See “Processor Module LEDs” on page 61.
4.
Verify that the front and rear Service Required LEDs are not lit.
See “Front Panel Controls and LEDs” on page 31 and “Rear Panel Controls and
LEDs” on page 33.
5.
Perform one of the following tasks based on your verification results:
■
If a fault was detected, see “Diagnostics Process” on page 25.
■
If no fault was detected, then the processor module was installed
successfully.