Verify the Front I/O Assembly
Servicing the Front I/O Assembly 131
3.
Tighten the retaining screw to secure the front I/O assembly to the motherboard.
4.
Connect the cable.
5.
Install the main module back into the server.
See “Install the Main Module” on page 95.
Related Information
■
“Remove the Front I/O Assembly” on page 127
■
“Verify the Front I/O Assembly” on page 131
Verify the Front I/O Assembly
1.
Ensure that you have completed the following:
■
Applied power to the server.
See “Connect the Power Cords” on page 191.
■
Started the system.
See “Power On the Server (Oracle ILOM)” on page 192.
2.
Log in to Oracle ILOM.
See “Log In to Oracle ILOM (Service)” on page 28.
3.
Start the faultmgmt shell.
-> start SP/faultmgmt/shell
Are you sure you want to start the faultmgmt shell (y/n)? y