Verify the Fan Module
Servicing Fan Modules 147
■
Started the system.
See “Power On the Server (Oracle ILOM)” on page 192.
2.
Check the front or rear panel LEDs for the following indications:
■
Green System OK LED – illuminated
■
Amber System Fault LED – not illuminated
■
Amber System Fan Fault LED – not illuminated
See “Front Panel Controls and LEDs” on page 31 and “Rear Panel Controls and
LEDs” on page 33 for the LED locations.
If these conditions are not met, perform the actions described in “Diagnostics
Process” on page 25.
3.
Log in to Oracle ILOM.
See “Log In to Oracle ILOM (Service)” on page 28.
4.
Start the faultmgmt shell.
-> start SP/faultmgmt/shell
Are you sure you want to start the faultmgmt shell (y/n)? y
faultmgmtsp>
5.
Use the fmadm faulty command to determine if the server is operating normally.
■
If a fault was detected, see “Diagnostics Process” on page 25.
■
If no fault was detected, the fan module was installed successfully.
Related Information
■
“Determine Which Fan Module Is Faulty” on page 142
■
“Install a Fan Module” on page 145