Determine Which DIMM Is Faulty (FMA)
74 SPARC T5-8 Server Service Manual • November 2015
Time UUID msgid Severity
------------------- ------------------------------------ ---------------- ---------
2013-01-18/21:04:40 7040d859-5b03-4a58-8dfd-e3a80875d62f SPSUN4V-8000-CQ MAJOR
Problem Status : solved
Diag Engine : fdd 1.0
System
Manufacturer : Oracle Corporation
Name : SPARC T5-8
Part_Number : 12345678+11+1
Serial_Number : xxxxxxxxxx
System Component
Manufacturer : Oracle Corporation
Name : SPARC T5-8
Part_Number : 12345678-+11+1
Serial_Number : xxxxxxxxxx
--------------------------------------------
Suspect 1 of 1
Fault class : fault.memory.dimm-ue
Certainty : 100%
Affects : /SYS/PM0/CM1/CMP/BOB0/CH0/D0
Status : faulted but still in service
FRU
Status : faulty
Location : /SYS/PM0/CM1/CMP/BOB0/CH0/D0
Manufacturer : Samsung
Name : 8192MB DDR3 SDRAM DIMM
Part_Number : 07042208,M393B1K70DH0-YK0
Revision : 04
Serial_Number : 00CE02121585C74755
Chassis
Manufacturer : Oracle Corporation
Name : T5 chassis
Part_Number : abcd
Serial_Number : dbca
Description: The number of correctable errors associated with this memory
module has exceeded acceptable levels.
Response : An attempt will be made to remove the affected memory from
service.
Impact : The dimm may be deconfigured at system restart which would
reduce total system memory capacity.
Action : Use 'fmadm faulty' to provide a more detailed view of this
event. Please refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-CQ for the latest
service procedures and policies regarding this diagnosis.
---------------------------------------------------------------------------
Related Information
■
“Determine Which DIMM Is Faulty (LEDs)” on page 75