Chapter 5
Interrupt Controller
V - 22 Control Registers
Group 12 Interrupt Control Register (G12ICR: 0x00008930) [8, 16-bit Access Register]
bp 1514131211109876543210
Flag - G12
LV2
G12
LV1
G12
LV0
-G12
IE2
G12
IE1
G12
IE0
-G12
IR2
G12
IR1
G12
IR0
-G12
ID2
G12
ID1
G12
ID0
At reset 0000000000000000
Access R R/W R/W R/W R R/W R/W R/W R R/W R/W R/W R R/W R/W R/W
bp Flag Description Set condition
15 - - -
14-12
G12LV2
G12LV1
G12LV0
Set an interrupt priority level Set a level 6 to 0
11 - - -
10 G12IE2
Timer 13 compare B interrupt enable flag 0: Disabled
1: Enabled
9G12IE1
Timer 13 compare A interrupt enable flag 0: Disabled
1: Enabled
8G12IE0
Timer 13 overflow/underflow interrupt enable
flag
0: Disabled
1: Enabled
7-- -
6G12IR2
Timer 13 compare B interrupt request flag 0: No interrupt request
1: Interrupt request
5G12IR1
Timer 13 compare A interrupt request flag 0: No interrupt request
1: Interrupt request
4G12IR0
Timer 13 overflow/underflow interrupt request
flag
0: No interrupt request
1: Interrupt request
3-- -
2G12ID2
Timer 13 compare/capture B interrupt detec-
tion flag
0: No interrupt detected
1: Interrupt detected
1G12ID1
Timer 13 compare/capture A interrupt detec-
tion flag
0: No interrupt detected
1: Interrupt detected
0G12ID0
Timer 13 overflow/underflow interrupt detec-
tion flag
0: No interrupt detected
1: Interrupt detected