Chapter 10
Motor Control PWM
Control Registers X - 11
10.2.5 PWM Period Setting Registers
PWM period setting register is used to determine the period for 3-phase of PWM0 and PWM1.
This register needs to be set only when double-buffer mode is selected. The value of PWMSETn is loaded into the
register at the timing selected with the PWM mode control register (PWMMDn). When the PWM counter is not
running, the double-buffer value is loaded into the register as is regardless of the specified read timing.
PWM0 Period Setting Register (PWMSET0: 0x0000A30C) [16-bit Access Register]
PWM1 Period Setting Register (PWMSET1: 0x0000A33C) [16-bit Access Register]
bp 1514131211109876543210
Flag PMS
ET0
F
PMS
ET0
E
PMS
ET0
D
PMS
ET0
C
PMS
ET0
B
PMS
ET0
A
PMS
ET0
9
PMS
ET0
8
PMS
ET0
7
PMS
ET0
6
PMS
ET0
5
PMS
ET0
4
PMS
ET0
3
PMS
ET0
2
PMS
ET0
1
PMS
ET0
0
At reset 0000000000000000
Access R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
bp Flag Description Setting condition
15-0
PMSET0F
to
PMSET00
Setting PWM0 period. Set the PWM0 16-bit counter period.
bp 1514131211109876543210
Flag PMS
ET1
F
PMS
ET1
E
PMS
ET1
D
PMS
ET1
C
PMS
ET1
B
PMS
ET1
A
PMS
ET1
9
PMS
ET1
8
PMS
ET1
7
PMS
ET1
6
PMS
ET1
5
PMS
ET1
4
PMS
ET1
3
PMS
ET1
2
PMS
ET1
1
PMS
ET1
0
At reset 0000000000000000