EasyManua.ls Logo

Panasonic MN103S

Panasonic MN103S
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 13
Serial Interface 2
XIII - 6 Control Registers
13.2.3 Serial Interface 2 Mode Register
These registers are readable/writable 8-bit registers that control serial interface 2
Serial Interface 2 Mode Register 0 (SC2CTR0: 0x0000A120) [8-bit Access Register]
Table:13.2.2 Serial Interface 2 Mode Register 0
bp 76543210
Flag SC2
CE1
--
SC2
DIR
SC2
STE
SC2
LNG2
SC2
LNG1
SC2
LNG0
At reset 00000111
Access R/W R R R/W R/W R/W R/W R/W
bp Flag Description Setting condition
7 SC2CE1
Transmission data output edge
Reception data input edge
Transmission data output edge
0: Falling
1: Rising
Reception data input edge
0: Rising
1: Falling
6-5 - - -
4 SC2DIR
Transfer bit specification 0: MSB first
1: LSB first
3SC2STE
Start condition selection 0: Without
1: With
2-0
SC2LNG2
SC2LNG1
SC2LNG0
Synchronous serial transfer bit count 000: 1bit
001: 2bit
010: 3bit
011: 4bit
100: 5bit
101: 6bit
110: 7bit
111: 8bit

Table of Contents