Chapter 8
8-bit Timer
Overview VIII - 3
Timer 14 Timer 15 Timer 16 Timer 17 Page
Interrupt cause NTMIRQ14 NTMIRQ15 NTMIRQ16 NTMIRQ17 -
Interval timer VIII-32
Timer output - - - VIII-36
Event count - - - VIII-38
Baud rate timer - VIII-32
Cascade connection - Connect with timer 14 Connect with timer 15 Connect with timer 16 VIII-40
Counter source IOCLK
IOCLK/8
IOCLK/32
IOCLK/128
Timer 15 underflow
Timer 16 underflow
IOCLK
IOCLK/8
IOCLK/32
Timer 14 underflow
Timer 16 underflow
Cascading with timer 14
IOCLK
IOCLK/8
IOCLK/32
IOCLK/128
Timer 14 underflow
Timer 15 underflow
Cascading with timer 15
IOCLK
IOCLK/8
IOCLK/32
Timer 14 underflow
Timer 15 underflow
Timer 16 underflow
TM17IO pin input
Cascading with timer 16
VIII-32