Chapter 14
A/D Converter
Operation XIV - 29
Power-down Mode
Power-down mode is used to minimize the standby power requirement. Set the ANnOFF flag of the ANnCTR0
register to “0”, for power-down mode and to “1” for operation mode. Set it to operation mode at conversion oper-
ation. 100 ns wait is required from operation mode starting to A/D converter starting.
Any Single Channel/One-time Conversion (AD0, AD1)
One channel A/D input is converted only once. The A/D interrupt is generated at the same time when conversion
ends. Set the channel number to be converted to the ANnCH2-0 flags of the ANnCTR0 register (conversion chan-
nel at any single channel conversion). When conversion is started by the ANnEN flag (conversion start-execution
flag), set the ANnTRG flag to “0” and the ANnEN flag to “1”. The ANnEN flag is “1” during conversion and “0”
after conversion ends.
Any Single Channel/One-time Conversion (AD2)
One channel A/D input is converted only once. The A/D interrupt is generated at the same time when conversion
ends. Set the channel number to be converted to the AN2CH3-0 flags of the AN2CTR0 register (conversion chan-
nel at any single channel conversion). When conversion is started by the AN2EN flag (conversion start-execution
flag), set the AN2TRG flag to “0” and the AN2EN flag to “1”. The AN2EN flag is “1” during conversion and “0”
after conversion ends.
Figure:14.3.2 Any Single Channel/One-time Conversion Timing
Start
Nch conversion
Stop
Interrupt request
Status
ANEN