User manual Rev. 01 — 12 January 2006 263
Philips Semiconductors
UM10161
Volume 1 Chapter 21: RealMonitor
RM_OPT_READHALFWORDS=TRUE
RM_OPT_WRITEHALFWORDS=TRUE
RM_OPT_READWORDS=TRUE
RM_OPT_WRITEWORDS=TRUE
Enables/Disables support for 8/16/32 bit read/write.
RM_OPT_EXECUTECODE=FALSE
Enables/Disables support for executing code from "execute code" buffer. The code must
be downloaded first.
RM_OPT_GETPC=TRUE
This option enables or disables support for the RealMonitor GetPC packet. Useful in
code profiling when real monitor is used in interrupt mode.
RM_EXECUTECODE_SIZE=NA
"execute code" buffer size. Also refer to RM_OPT_EXECUTECODE option.
RM_OPT_GATHER_STATISTICS=FALSE
This option enables or disables the code for gathering statistics about the internal
operation of RealMonitor.
RM_DEBUG=FALSE
This option enables or disables additional debugging and error-checking code in
RealMonitor.
RM_OPT_BUILDIDENTIFIER=FALSE
This option determines whether a build identifier is built into the capabilities table of
RMTarget. Capabilities table is stored in ROM.
RM_OPT_SDM_INFO=FALSE
SDM gives additional information about application board and processor to debug tools.
RM_OPT_MEMORYMAP=FALSE
This option determines whether a memory map of the board is built into the target and
made available through the capabilities table
RM_OPT_USE_INTERRUPTS=TRUE
This option specifies whether RMTarget is built for interrupt-driven mode or polled mode.
RM_FIFOSIZE=NA
This option specifies the size, in words, of the data logging FIFO buffer.