Default: 3 packets
The MED Fast Start Count parameter is part of the timer which ensures that the
LLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Start is
critical to the timely startup of LLDP, and therefore integral to the rapid availability
of Emergency Call Service.
Button
: Click to apply changes.
Figure 4-12-2: LLDP Global Config Page Screenshot
The page includes the following fields:
Object Description
LLDP Enable
Display the current LLDP status.
LLDP PDU Disable
Action
Displays the current LLDP PDU disable action.
Transmission Interval
Display the current transmission interval informaiton.
Check-Change Interval
Display the current check-change interval informaiton.
Reinitialization Delay
Display the current reinitialization delay informaiton.
Transmit Delay
Displays the current transmit delay informaiton.
LLDP-MED Fast Start
Repeat Count
Display the current LLDP-MED Fast Start Repeat Count informaiton.