ESP-LXIVM Series Controllers
Station Sequencing
Allows you to optimize water windows by controlling the sequence in
which stations can run.
Choose from 2 methods:
1. Sequence by Station Number - (system default).
2. Sequence by Station Priority - required when using Flo-Manager®
(LX-IVM Pro only). This option decreases the overall time required
to complete watering when operating multiple stations simultane-
ously.
Station Sequencing by Station Number (Default)
Stations will operate in the following order:
1
Station
number
LX-IVM has a capacity of 60 stations.
LX-IVM Pro has a capacity of up to 240 Stations.
2
Program
assignment
LX-IVM has 10 independent Programs available.
LX-IVM Pro has 40 independent Programs available.
NOTICE
Non-irrigation priority stations will always be selected to oper-
ate first.
Station Sequencing by Station Priority
Stations will operate in the following order:
1
Station
priority
Non-Irrigation > High > Medium > Low
2
Station run
time
Longest run time > shortest run time
3
Station
number
LX-IVM has a capacity of 60 stations.
LX-IVM Pro has a capacity of up to 240 Stations.
4
Program
assignment
LX-IVM has 10 independent Programs available.
LX-IVM Pro has 40 independent Programs available.
NOTICE
If Flo-Manager® (LX-IVM Pro only) is turned ON, then the
default Station Sequencing setting is Sequence by Station
Priorities. To select Station Sequencing by Station Number,
Flo-Manager® must first be turned OFF. See "Set Flo-Man-
ager®" on page 83 for more details.