ESP-LXIVM Series Controllers
Delayed Recall Programs
Use the Delayed Recall feature to automatically replace the currently
loaded programs with a previously stored program at a future date.
NOTICE
Once current programs have been replaced with the Delayed
Recall feature, they can not be restored.
Turn the controller dial to Advanced Settings

At the IQ / ADVANCED screen, with Store/Recall Programs
selected, press Next.

At the Program Options screen, press the Down Arrow key to
select Delayed Recall, then press Next.
IQ / ADVANCED
Next
About this LX-IVM
Configure Cartridge
Factory Defaults
Store/Recall Programs
Program Options
Next
Clear Programs
Delayed Recall
Recall Programs
Store Programs

At the Recall Delay screen, press the + and – keys to set the num-
ber of days (from 0 to 90 days) before Contractor Defaults are
restored. For example, set it to 7 days if you want your original
programs to be restored in one week.
To clear a Delayed Recall, set the number of days to 0.
Done
Recall Delay
Days Remaining
01