Command reference
R&S
®
ZNA
1399User Manual 1178.6462.02 ─ 20
Example:
*RST; SOUR:POW 5
Define a base channel power of +5 dBm. This power is also
used as an (initial) power for all test ports and external genera-
tors.
SOUR:POW1:OFFS -5, CPAD
Change the source power at test port no. 1 to 0 dB without
affecting the power at the remaining ports.
SWE:AXIS:POW 'Port 1; Source'
Select the source signal at port 1 as the reference signal for
power definitions.
SOUR:POW -5
Shift all powers by -5 GHz.
SWE:AXIS:POW 'Port 2; Source'
Select the source signal at port 2 as the reference signal for
power definitions.
SOUR:POW?
Query the power at test port 2. The response is 0.
Manual operation:
See "Stimulus Axis – Frequency / Power" on page 475
[SENSe<Ch>:]SWEep:COUNt <Sweep>
Defines the channel-specific number of sweeps to be measured and buffered in single
sweep mode (INITiate<Ch>:CONTinuous OFF). Use [SENSe:]SWEep:COUNt:
ALL to define the sweep count for all channels.
If controlled timing is active (INITiate<Ch>:CTIMing ON), then also in continuous
sweep mode (INITiate<Ch>:CONTinuous ON) this setting defines the number of
sweeps to be buffered (ring buffer).
Suffix:
<Ch>
.
Channel number
Parameters:
<Sweep> Number of consecutive sweeps to be measured and buffered.
Range: 1 to 100000
*RST: 1
Example: See CALCulate<Chn>:DATA:NSWeep:FIRSt?
Manual operation: See "Sweeps/Memory Size" on page 512
[SENSe<Ch>:]SWEep:CTIMing:STIMe <Value>
In controlled timing mode (INITiate<Ch>:CTIMing ON, this command allows you to
set the wait time manually.
This user-defined wait time only takes effect if [SENSe<Ch>:]SWEep:CTIMing:
STIMe:MODE is set to ON.
Suffix:
<Ch>
.
Channel number
SCPI command reference