GUI reference
R&S
®
ZNA
691User Manual 1178.6462.02 ─ 20
Type
Switches between "Deembedding" and "Embedding" network definition.
Logical Port
Logical analyzer port, as defined in the "Balanced Ports" configuration. The transfor-
mation networks are defined such that the physical analyzer test ports are connected
to the left of the circuit; the DUT ports are on the right side.
You can define independent transformation networks for all balanced ports.
Remote command:
The <LogPt> numeric suffix in the embedding/deembedding commands identifies the
logical port; see e.g. CALCulate<Ch>:TRANsform:VNETworks:BALanced:
EMBedding<LogPt>[:STATe].
All Deembedding Activated
Deactivates or activates all deembeddings (single-ended, balanced, port set, ground
loop) for the active channel, if any.
This control is only visible if Type = "Deembedding".
Remote command:
n.a.
Network
The graphical list contains all available 4-port networks (see Chapter 4.6.2.4, "Circuit
models for 4-port networks", on page 210).
The
symbol selects "no network" and disables deembedding/embedding for the
selected balanced port.
The 4-port data network (symbol "D1" only) is defined by means of an s4p file (see D1,
D2). For deembedding, the s4p file can also be generated by a third-party fixture mod-
eling tool (see "Fixture Tool" on page 672).
Other 2-port data-subnetworks (symbols "D1" and "D2") are defined by means of s2p
files (see Network).
The parameters of lumped elements are displayed below the graphical list.
Tip:
Drag and drop the network symbols in horizontal or vertical direction to switch to
the next symbol. The lumped elements and S-parameter networks ("D1", "D2") are
numbered from top to bottom.
Use the Conductance in Embedding Networks switch to change from resistances
in "Capacitor in parallel with resistor" circuit blocks to conductances and vice versa.
Remote command:
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
TNDefinition
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
PARameters:C<Cmp>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
PARameters:L<Cmp>
CALCulate<Ch>:TRANsform:VNETworks:BALanced:DEEMbedding<LogPt>:
PARameters:R<Cmp>
Offset Embed softtool