GUI reference
R&S
®
ZNA
765User Manual 1178.6462.02 ─ 20
Select "Available Cable Types..." to access the list of predefined and user-defined
cable types (see Chapter 5.17.3.2, "Available Cable Types... dialog", on page 766).
Remote command: 
CALCulate<Chn>:TRANsform:DTFault:SELect
Fault Limit Check
Enables/disables checking the current "Distance to Fault" trace for spikes above the
given Fault Limit (red line).
The fault limit is defined relative to the 0 dB-line in the test diagram, i.e. the peak
response value for total reflection after proper calibration.
Note that the fault limit is handled like any other limit line. When "Fault Limit Check" is
enabled, the current "Fault Limit" forms a new upper line segment replacing other pre-
viously defined limit lines (see Chapter 5.6.1.2, "Define Limit Lines dialog",
on page 435).
Remote command: 
CALCulate<Chn>:TRANsform:DTFault:PEAK:STATe
Fault Limit
Determines the level above which peaks in the active "Distance to Fault" trace are con-
sidered as faults.
The fault limit is defined relative to the 0 dB-line in the test diagram, i.e. the peak
response value for total reflection after proper calibration.
Note:
Applic softtool